Open Access

Table 8

Permeabilities, resistance factors, and polymer in-situ viscosities measured by each pressure sensor and in each injection.

Property Unit new EOR-Grade Scleroglucan
Full core Pressure tap 1 Pressure tap 2 Pressure tap 3
Position relative to injection face cm 0 11.43 ± 0.01 16.51 ± 0.01 21.59 ± 0.01
Absolute permeability mD 336 ± 4 334 ± 5 301 ± 6 264 ± 7
ko at swi for O1 mD 266 ± 8 235 ± 10 217 ± 12 197 ± 14
kw at sor for WF mD 65.0 ± 1.6 66.3 ± 2.9 52.7 ± 2.8 42.1 ± 3.0
ko at swi for O2 mD 155 ± 5 182 ± 9 170 ± 9 158 ± 11
kw at sor for WPF mD * 76.9 ± 3.2 67.6 ± 3.5 57.0 ± 4.0
RF at sor for PF 2.73 ± 0.01 2.54 ± 0.04 2.28 ± 0.02 2.16 ± 0.02
RRF at sor for WPF * 0.86 ± 0.01 0.78 ± 0.01 0.74 ± 0.01
ηp,in-situ at sor for PF mPa s * 1.61 ± 0.04 1.60 ± 0.03 1.59 ± 0.02
is s−1 * 357 ± 15 381 ± 17 415 ± 21
*

These properties could not be estimated due to a pressure sensor malfunction.