Open Access

Table A2

Details of validation of the different thermodynamic packages in simulation of the existing NGL plant.

Parameter Current value PR Error (%) Mod. PR Error (%) SRK Error (%)
Temp. of 52 (°C) −35.00 −36.30 3.70 −36.02 2.91 −35.28 0.79
Temp. of 54 (°C) −66.80 −66.96 0.24 −66.70 0.15 −65.94 1.29
Temp. of 56 (°C) 16.20 17.31 6.87 16.82 3.83 16.34 0.86
Temp. of 58 (°C) 36.30 37.71 3.89 37.88 4.35 36.28 0.04
Temp. of 63 (°C) 8.70 7.69 11.65 7.74 11.06 7.30 16.06
Temp. of 64 (°C) 104.60 104.50 0.10 104.61 0.01 104.59 0.01
Temp. of 86 (°C) 89.50 91.62 2.37 91.70 2.46 90.70 1.45
Temp. of 91 (°C) 60.00 60.36 0.60 60.34 0.57 59.96 0.07
Temp. of 248 (°C) −87.20 −87.10 0.12 −87.13 0.08 −86.63 0.65
Flow of 58 (kmol hr−1) 1729 1709 1.19 1695 1.92 1775 2.62
Flow of 63 (kmol hr−1) 954 924 3.15 909 4.63 989 3.74
Flow of 91 (kmol hr−1) 920 938 2.02 939 2.08 938 1.98
C5+ content of 89 (%mol) ≤0.0032 0.0120 275.72 0.0019 0.00 0.0119 272.79
Deethanizer cond. duty (kW) 4020 3585 10.83 3548 11.47 3545 11.83
Depropanizer cond. duty (kW) 11 980 11 744 1.97 11 759 1.85 11 805 1.46
Debutanizer cond. duty (kW) 6500 5532 14.89 6338 2.49 5546 14.68
Demethanizer reb. duty (kW) 3450 3648 5.75 3568 3.43 3016 12.57
Deethanizer reb. duty (kW) 7670 7253 5.43 7182 6.36 7499 2.23
Depropanizer reb. duty (kW) 11 430 11 093 2.95 11 112 2.78 11 116 2.74
Debutanizer reb. duty (kW) 4695 3878 17.41 4686 0.19 3867 17.64
Average error (%) 18.54 3.13 18.28