Dossier: Chemical Reactors, from Mock-up to Industriel Reactor: Diagnostic Methods - Rencontres Scientifiques IFP, Solaize, Dec. 1999
Open Access
Issue
Oil & Gas Science and Technology - Rev. IFP
Volume 55, Number 4, July-August 2000
Dossier: Chemical Reactors, from Mock-up to Industriel Reactor: Diagnostic Methods - Rencontres Scientifiques IFP, Solaize, Dec. 1999
Page(s) 407 - 415
DOI https://doi.org/10.2516/ogst:2000029
Published online 01 October 2006
  • Beck, M.S., Dyakowski, T. and Williams, R.A. (1997) Process Tomography–The State of the Art. Proc. Frontiers in Industrial Process Tomography II, Delft, The Netherlands, 357-362.
  • Bemer, G.G. and Zuiderweg, F.J. (1978) Radial Liquid Spread and Maldistribution in Packed Columns under Different Wetting Conditions. Chem. Eng. Sci., 33, 1637-1643. [CrossRef]
  • Borda, M.,Gabitto, J.F. and Lemcoff, N.O. (1987) Radial Liquid Distribution in a Trickle-Bed Reactor. Chem. Eng. Comm., 60, 243-252. [CrossRef]
  • Chaouki, J.F.,Larachi, F. and Dudukovic, M.P. (1997) Noninvasive Tomographic and Velocimetric Monitoring of Multiphase Flows. Ind. Eng. Chem. Res., 36, 4476-4503. [CrossRef]
  • Herskowitz, M. and Smith, J.M. (1978) Liquid Distribution in Trickle-Bed Reactors. Part II: Tracer Studies. AIChE J., 24, 450-454. [CrossRef]
  • Hoek, P.J.,Wessinlingh, J.A. and Zuiderweg, F.J. (1986) Small Scale and Large Scale Liquid Maldistribution in Packed Columns. Chem. Eng. Res. Des., 64, 431-449.
  • Kennedy, C.R. and Jaffe, S.B. (1986) Analysis of Tracer Experiments from Commercial-Scale Trickle-Bed Reactors. Chem. Eng. Sci., 41, 845-853. [CrossRef]
  • Kouri, R.J. and Sohlo, J. (1996) Liquid and Gas Flow Patterns in Random Packing. Chem. Eng. J., 61, 95-105.
  • Lutran, P.G.,Ng, K.M. and Delikat, E.P. (1991) Liquid Distribution in Trickle Beds. An Experimental Study using Computer-Assisted Tomography. Ind. Eng. Chem. Res., 30, 1270-1280. [CrossRef]
  • Marcandelli, C.,Wild, G.,Lamine, A.S. and Bernard, J.R. (1999) Measurements of Local Particle-Fluid Heat Transfer Coefficient in Trickle-Bed Reactors. Chem. Eng. Sci., 54, 4997-5002. [CrossRef]
  • Moller, L.B.,Halken, C.,Hansen, J.A. and Bartholdy, J. (1996) Liquid Gas Distribution in Trickle-Bed Reactors. Ind. Eng. Chem. Res., 35, 926-930. [CrossRef]
  • Reinecke, N. (1996) Kapazitive Tomographie für transiente Mehrphasenströmungen. Thesis, Fakultät für Maschinenwesen, Hanover, Germany.
  • Reinecke, N. and Mewes, D. (1996a) Recent Developments and Industrial/Research Applications of Capacitance Tomography. Meas. Sci. Technol., 7, 233-246. [CrossRef]
  • Reinecke, N. and Mewes, D. (1996b) Tomographic Imaging of Trickle-Bed Reactors. Chem. Eng. Sci., 51, 2131-2138. [CrossRef]
  • Reinecke, N.,Petritsch, G.,Schmitz, D. and Mewes, D. (1998) Tomographic Measurement Techniques–Visualisation of Multiphase Flows. Chem. Eng. Technol., 21, 7-18. [CrossRef]
  • Ross, L.D. (1965) Performance of Trickle-Bed Reactors. Chem. Eng. Prog., 61, 77-82.
  • Sapre, A.V.,Anderson, D.H. and Krambeck, F.J. (1990) Heater Probe Technique to Measure Flow Maldistribution in Large Scale Reactors. Chem. Eng. Sci., 45, 2263-2268. [CrossRef]
  • Saroha, A.K.,Nigam, K.D.P.,Saxena, A.K. and Kapoor, V.K. (1998) Liquid Distribution in Trickle-Bed Reactors. AIChE J., 44, 2044-2052. [CrossRef]
  • Sylvester, N.D. and Pitayagulsarn, P. (1975) Radial Liquid Distribution in Cocurrent Two-Phase Downflow in Packed Beds. Can. J. Chem. Eng., 53, 599-605. [CrossRef]
  • Toye, D.,Crine, M.,Marchot, P. and L’Homme, G. (1996) Modelling of the Multiphase Flow in Packed Beds by Computer Assisted X-ray Tomography. Meas. Sci. Technol., 7, 436-443. [CrossRef]
  • Toye, D., Crine, M., Marchot, P. and L’Homme, G. (1997) Modelling of the Liquid Distribution in a Packed Column Based upon X-ray Tomography Images. Proc. Frontiers in Industrial Process Tomography II, Delft, The Netherlands, 337-342.
  • Trambouze, P.H., van Landeghem and Wauquier, J.P. (1984) Les r蠣teurs chimiques, Ȥ. Technip, Paris.
  • Vergel Hernandez, C.A. (1993) Les réacteurs catalytiques à lit fixe avec écoulement de gaz et de liquide. Comparaison sur les plans théoriques et expérimentaux du réacteur dans différents sens d’écoulement. PhD Thesis, Institut national polytechnique de Lorraine, Nancy, France.
  • Vergel, C.,Euzen, J.P.,Trambouze, P. and Wauquier, J.P. (1995) Two-Phase Flow Catalytic Reactor, Influence of Hydrodynamics on Selectivity. Chem. Eng. Sci., 50, 3303-3312. [CrossRef]
  • Villermaux, J. and van Swaaij, W.P.M. (1969) Modèle représentatif de la distribution des temps de séjour dans un réacteur semi-infini à dispersion axiale avec des zones stagnantes. Application à l’écoulement ruisselant dans les colonnes d’anneaux Raschig. Chem. Eng. Sci., 24, 1097-1111. [CrossRef]
  • Williams, R.A. and Xie, C.G. (1993) Tomographic Techniques for Characterising Particulate Processes. Part. Syst. Charact., 10, 252-261. [CrossRef]
  • Yang, X.L., Euzen, J.P.and Wild, G. (1990) Residence Time Distribution of the Liquid in Gas-Liquid Cocurrent Upflow Fixed-Bed Reactors with Porous Particles. Chem. Eng. Sci., 45, 3311-3317. [CrossRef]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.