Table 1
Non-vaporizing spray test conditions.
| Test cases (unit) | Case-1 | Case-2 | Case-3 |
|---|---|---|---|
| Injection pressure (bar) | 600 | 900 | 1500 |
| Injection duration (ms) | 5.0 | 5.0 | 1.54 |
| Fuel mass injected (mg) | 18.0 | 22.15 | 3.46 |
| Nozzle diameter (mm) | 0.150 | 0.150 | 0.084 |
| Ambient pressure (bar) | 60 | 60 | 30 |
| Ambient temperature (K) | 343 | 343 | 363 |
| Fuel temperature (K) | 333 | 333 | 440 |