Table 5
Summary of temperature measurement with thermocouples under spray A conditions [2, 3].
Institution | Facility | Thermocouple type | Error corrections |
|||
---|---|---|---|---|---|---|
Hypothesis | Convection | Radiation | Estimated correction | |||
Sandia | CVP | Bare bead type-R (50 μm): Pt/Pt+13Rh | Conduction error neglected | Yes | Yes | 4–10 K (at 900 K) |
TUE | CVP | Bare bead type-R (50 μm): Pt/Pt+13Rh | Yes | Yes | 4–10 K (at 900 K) | |
IFPEN | CVP | Bare bead type-K (50 μm): Ni/Cr | Yes | Yes | 4–10 K (at 900 K) | |
Caterpillar | CPF | Sheathed type-K (1 and 3 mm): Ni/Cr |
|
No correction (temperature time averaged) | Yes | – |
CMT | CPF | Sheathed type-K : Ni/Cr |
|
No correction (temperature time averaged) | Yes | – |