Open Access

Table 2

Column parameters used in HSDM validation study.

Parameter Test 1 Test 2 Test 3 Test 4 Test 5
Height, L (cm) 10 10 23 23 23
Bed diameter, D (cm) 1.5 2.6 4.6 2.6 4.6
Intraparticle porosity, ε 0.85 0.85 0.85 0.85 0.85
Bed porosity, εb 0.48 0.46 0.35 0.45 0.36
Particle diameter, dp (mm) 1 1 1 1 1
Particle density, ρp (g/cc) 1.04 1.04 1.04 1.04 1.04
Equivalent bed mass, M (g) 9 29 255 70 255
MDEA flow rate, Q (mL/min) 0.75 0.75 4.3 0.75 1
Empty bed contact time (min) 23.5 71 89 163 382
Superficial velocity, Us (cm/min) 0.42 0.14 0.26 0.14 0.06
Residence time, T (min) 8.45 25.4 34 58 137
Freundlich coefficient, KF ((mg/g)(L/mg)n) 0.0015 0.0015 0.0015 0.0015 0.0015
Freundlich exponent, n 0.8 0.8 0.8 0.8 0.8
Film mass transfer coefficient, kL (cm/s) 6.9E-05 4.8E-05 5.3E-05 4.8E-05 5.1E-05
Surface diffusion coefficient, Ds (cm2/s) 2.4E-06 2.4E-06 2.4E-06 2.4E-06 2.4E-06
Stanton number, St 1.1 2.4 3.7 5.6 10.5
Biot number, Bi 1.07 0.76 0.97 0.76 0.61