Table 3
Technological parameters of alkylation process.
Parameter | Value |
---|---|
Alkenes flowrate, m3/h | 41.16 |
Circulating isobutene flowrate, m3/h | 120.16 |
Coolant flowrate to contactor 1, m3/h | 25.03 |
Coolant flowrate to contactor 2, m3/h | 40.90 |
Coolant flowrate to contactor 3, m3/h | 40.90 |
Coolant flowrate to contactor 4, m3/h | 37.09 |
Inlet temperature in contactor 1, °C | 5.00 |
Inlet temperature in contactor 2, °C | 1.88 |
Inlet temperature in contactor 3, °C | 0.51 |
Inlet temperature in contactor 4, °C | −0.35 |
Feedstock pressure, MPa | 0.16 |