7th Takreer Research Centre Symposium
Open Access

Table 4

Quantitative DCMD system metrics summary for different sensitivity studies on membrane properties (at Re = 100, and 75 °C feed temperature).

Parameter Growth/reduction factor Average mass flux, J″ (kg/m2 h) J″ Loss/gain (%) Average thermal efficiency, η (%) η Loss/gain (%)
Porosity*
 85% 1.0625 48.89 +12.91 71.23 +3.7
 80% 1 43.30 Baseline 68.69 Baseline
 75% 0.9375 38.06 −12.10 65.86 −4.12
 60% 0.75 24.36 −43.74 55.29 −19.51
 40% 0.5 13.70 −68.36 41.08 −40.20
Pore size**
 200 nm 2 88.69 +104.8 81.75 +19.01
 100 nm 1 43.30 Baseline 68.69 Baseline
 50 nm 0.5 21.39 −50.6 52.08 −24.18
Superhydrophobicity***
 No-slip 43.30 Baseline 68.69 Baseline
 Slip 50.27 +16.10 69.03 +0.49

*At 0.1 µm pore size.

**At 80% porosity.

***At 0.1 µm pore size, 80% porosity.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.