Open Access

Table 2

Settings of boundaries and solutions.

Types Items Settings
Boundaries Inlet Total mass discharge and corresponding IGVF
Outlet Average static pressure
Wall No-slip
Rotor-stator interfaces Frozen-stator
Solutions Advection term Second order upwind scheme
Turbulence term Second order upwind scheme
RMS residual 1 × 10−4