Figure 6

Download original image
Validation of the low-diffusive interface capturing scheme on the Kothe-Rider advection case, mesh 5002. Plot of the passive variable z ∈ [0, 1] on the left column, and interface smearing indicator μ = z(1 − z) in the right column. a) At initial time t = 0, b) at time t = 3, c) at time t = 6, d) at time t = 9, e) at final time t = 12.