Table 9
Triaxial test data and Mohr circle results for condition 2 (120 PCF).
Test parameters | 2-A | 2-B | 2-C | 2-D | 2-E |
---|---|---|---|---|---|
Standard | ASTM D2664 | ASTM D2664 | ASTM D2664 | ASTM D2664 | ASTM D2664 |
Peak stress (MPa) | 38 | 54 | 47 | N/A | N/A |
Diameter (mm) | 38.30 | 38.33 | 38.10 | N/A | N/A |
Height (mm) | 79.10 | 90.30 | 78.60 | N/A | N/A |
Loading rate (MPa/s) | 0.08 | 0.08 | 0.08 | N/A | N/A |
C (MPa) | 6 | 8 | 0.8 | N/A | N/A |
Φ | 20 | 23 | 33 | N/A | N/A |