Open Access

Table 1

Comparison of induction time measurement obtained from convention visual method and temperature augmented visual method.

Hydrate Inhibitors Concentration (wt/vol%) Induction Time (minutes) Induction Time Difference/Error

Conventional Visual Method Temperature Augmented Visual Method
Luvicap 55W 0.1 155 140 15
0.3 714 700 14
0.5 >1440 >1440
0.7 >1440 >1440
1.0 >1440 >1440
PNIPAM 0.1 107 95 12
0.3 476 460 16
0.5 1217 1200 17
0.7 1395 1380 15
1.0 >1440 >1440
PVP 0.1 92 80 12
0.3 215 200 15
0.5 1016 1000 16
0.7 1241 1230 11
1.0 >1440 >1440
PAM 0.1 08 10 02
0.3 08 10 02
0.5 11 12 01
0.7 09 14 05
1.0 12 15 03

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.